DSHELL MATERIAL
Can be customized
Product parameters
Â
Model | volume(L) | High(mm) | Diameter(mm) | Caliber | Preset Pressure | Connection Size |
HYMZ-0.35 | Â Â 0.35 | Â 235 | Â Â 142 | DN15 | Â Â Â Â 1.6 | 1/2" |
HYMZ-0.6 | Â Â 0.6 | Â 250 | Â Â 174 | DN20 | Â Â Â Â 1.6 | 3/4" |
HYMZ-1.0 | Â Â 1.0 | Â 310 | Â Â 210 | DN25 | Â Â Â Â 1.6 | 1" |
HYMZ-2.0 | Â Â 2.0 | Â 330 | Â Â 280 | DN32 | Â Â Â Â 1.6 | 1 +1/4" |
HYMZ-4.0 | Â Â 4.0 | Â 370 | Â Â 306 | DN40 | Â Â Â Â 1.6 | 1+1/2"Â |
HYMZ-4.0 | Â Â 4.0 | Â 370 | Â Â 306 | DN50 | Â Â Â Â 1.6 | 2" |
Product can be customized according to your demands
Volume selection method:
Pulsation Damper volume = Every stroke volume (ml) *15
A PULSATION DAMPER
Â
1. The ability to minimize pulsations, vibrations, and water hammer means that this component-
provides excellent protection and smooth system flow.
2. Protection of pipes, meters, valves and instrumentation from pulsation and vibration
3. Used together with back pressure valve can make pressure fluctuation close to zero.
4. Limit damaging pressure surges caused by pump start-up and shut-down.
5. Prevention of foaming and splashing
6. Allows more accurate readings when pumping through mass flow meters & other instruments
Â
DESIGN FEATURES
The container is often divided into two sides by a flexible membrane , one containing compressibe nitrogen gas,
and the other side through which the liquid goes. Convenient maintenance, long-term stable operation
APPLICATION
 In a metering system constant flow is normally required. A damper is essential to reduce the flow fluctuations-
to ensure process control and mixing. Â
In pipes pressure pulsation will shake the piping and dampening the pulses prevents fatigue and connection failures.
In general removing pulsation reduced the energy usage to transmit liquid over distances
Â
Where is a Pulse Dampener installed ?
For best performance a Pulsation Dampener should be installed at the start of the pipe down-
which the flow has to be forced or when the dampener is to perform as a suction side acceleration head loss reducer,
then the installation is after the suction supply line at the entry to the pump inlet check valve.
Generally A pulsation dampner is installed as close to the source of the pulsation as possible.
Instructions
COMPANY INFOTMATION
FAQ
1. Q: Are you a factory or trading company?
   A: We are a factory. Â
 2. Q: What're your payments ?Â
   A: T/T,Western Union,L/C etc.
 3. Q: What about the package ?
   A: Standard export plywood case or carton.
Â
If you want to know more details, Please send inquiry to me,
Â
DSHELL MATERIAL
Can be customized
Product parameters
Â
Model | volume(L) | High(mm) | Diameter(mm) | Caliber | Preset Pressure | Connection Size |
HYMZ-0.35 | Â Â 0.35 | Â 235 | Â Â 142 | DN15 | Â Â Â Â 1.6 | 1/2" |
HYMZ-0.6 | Â Â 0.6 | Â 250 | Â Â 174 | DN20 | Â Â Â Â 1.6 | 3/4" |
HYMZ-1.0 | Â Â 1.0 | Â 310 | Â Â 210 | DN25 | Â Â Â Â 1.6 | 1" |
HYMZ-2.0 | Â Â 2.0 | Â 330 | Â Â 280 | DN32 | Â Â Â Â 1.6 | 1 +1/4" |
HYMZ-4.0 | Â Â 4.0 | Â 370 | Â Â 306 | DN40 | Â Â Â Â 1.6 | 1+1/2"Â |
HYMZ-4.0 | Â Â 4.0 | Â 370 | Â Â 306 | DN50 | Â Â Â Â 1.6 | 2" |
Product can be customized according to your demands
Volume selection method:
Pulsation Damper volume = Every stroke volume (ml) *15
A PULSATION DAMPER
Â
1. The ability to minimize pulsations, vibrations, and water hammer means that this component-
provides excellent protection and smooth system flow.
2. Protection of pipes, meters, valves and instrumentation from pulsation and vibration
3. Used together with back pressure valve can make pressure fluctuation close to zero.
4. Limit damaging pressure surges caused by pump start-up and shut-down.
5. Prevention of foaming and splashing
6. Allows more accurate readings when pumping through mass flow meters & other instruments
Â
DESIGN FEATURES
The container is often divided into two sides by a flexible membrane , one containing compressibe nitrogen gas,
and the other side through which the liquid goes. Convenient maintenance, long-term stable operation
APPLICATION
 In a metering system constant flow is normally required. A damper is essential to reduce the flow fluctuations-
to ensure process control and mixing. Â
In pipes pressure pulsation will shake the piping and dampening the pulses prevents fatigue and connection failures.
In general removing pulsation reduced the energy usage to transmit liquid over distances
Â
Where is a Pulse Dampener installed ?
For best performance a Pulsation Dampener should be installed at the start of the pipe down-
which the flow has to be forced or when the dampener is to perform as a suction side acceleration head loss reducer,
then the installation is after the suction supply line at the entry to the pump inlet check valve.
Generally A pulsation dampner is installed as close to the source of the pulsation as possible.
Instructions
COMPANY INFOTMATION
FAQ
1. Q: Are you a factory or trading company?
   A: We are a factory. Â
 2. Q: What're your payments ?Â
   A: T/T,Western Union,L/C etc.
 3. Q: What about the package ?
   A: Standard export plywood case or carton.
Â
If you want to know more details, Please send inquiry to me,
Â
3Tons Electric Hydraulic Jack bearing capacity within 3 tons and 35cm lifting height,
3 In 1 Electric Hydraulic Jack,Electric Car Jack 5 Ton 12V,Electric Car Hydraulic Jack,20 Ton Electric Jack
JINYUN TIANYANG TOOLS CO.,LTD. , https://www.tianyang-tool.com