Product highlights
* Multilingual operation
* Automatic built in test and self diagnosis
* Secure access Key
* Uninterruptable Power Supply (UPS)
* Threat alert and material classification
* Auto archiving
* Network-Ready
* Energy saving design
* One key turn off
* Drugs and explosives inspection
* Indication of the date and time
* baggage counter
Physical Specifications | Â |
Unit weight (kgs) | 455 |
Unit size (mm) | 2007.5(L)*868(W)*1314(H) |
after packed in wooden pallet -Â | Â |
Gross weight (kgs) | 500 |
Packing size | #1: 212*101*156cm |
 | #2: 87*87*141cm |
 | |
General Specifications | Â |
Tunnel size(mm) | 615(L)*418(W) |
Conveyor Speed(m/s) | 0.22 |
Conveyor height(mm)Â | 680.5 |
Conveyor Max Load(kgs) | 150 |
X ray dose per each inspection | 1.5 μGy |
X ray leakage | <0.25 μGy / h |
Penetration | 43mm steel |
Wire Resolution | dia 0.0787mm copper wire (AWG40) |
Penetration Resolution | dia 0.16mm copper wire (AWG34) under three-step aluminum wedge 9.5mm, 15.9mm, 22.2mm |
Spatial resolution: | dia1.0mm,Vertical: dia1.0mm |
Power Consumption | max. 1KW |
Noise | < 58 dB |
Film Safety | Guarantee ASA/ISO1600 Film |
 |  |
X-ray Generator (single) | Â |
Anode Voltage | Spellman 160 KV |
Anode power | 0.4-1.2mA (adjustable) |
Generate angle | 80 degree upward |
Generate direct | from bottom to top |
Cooling / Duty Cycle | Oil Cooling /100%Â |
Brand | Spellman |
 |  |
Image System | Â |
X-ray Sensor | L-Shaped Photodiode Array (multi-energetic)Â , 12bit Deep |
Image Display | High resolution of 1024 * 1280 pixel; Image Grey Level: 4096 |
Image Enhancement | 1-64times enlargement continuity, Color/BW, negative, high/low penetration, organic /inorganic Stripping, general enhancement, and pseudo color, etc. |
Image Recall | Â All preceding images recallable, retrieval |
Explosives & Narcotics Detection | Explosives & narcotics alarm and highlight according to atomic number signature |
High Density Region Alarm | Impenetrable region alarm and highlight, for possible concealing of threats and contrabands |
Threat Image Projection | Inserting fictional, but realistic images of threat items into baggage during screening operation, for maintenance of vigilance, as well as training and assessment of image identification capability |
Image Archive | Up to 100,000 images stored automatically, enable transferring to USB disk, and converting to JPG, BMP and other general formats |
Miscellaneous Functions | Time/date display, counters, user management, system-on/X-ray-on timers, power on self test, built-in diagnostic facilities, dual-direction scanning, system log, system standby and stimulant training, ADS etc. |
Network Applications | Multiple remote applications available based on Ethernet LAN and windows platform, such as image centralized storage and identify, recheck workstation, and network TIP, etc ( Optional) . |
Images process | 24bit real time processing ,4colors analysis, Images displayed marked date and ID NO ,Count the number of bags |
 |  |
Operating Environment | Â |
Operation temperature/Humidity |  0ºC-45ºC / 5%-95%(non-condensing) |
Storage Temperature/Humidity |  -40ºCto 70ºC / 5%-95%(non-condensing) |
Operation Power |  220VAC(±10%) 50±3Hz (Optional: 100VAC,110VAC,120VAC,200VAC) |
UPS | Â 15mins, 30mins, 60mins etc, optional |
 |  |
Computer and other | Â |
Monitor | High Resolution Color, LCD Accord, 17inch |
Hard Disk | SEAGATE 500G 3.5" |
CPU | G1610 2.6G |
Storage | 2GB 1600MHz DDR3 Innodisk |
Main board | H61 SYM76993VGGAÂ |
 |  |
Compliance | Â |
International | * ISO19001 ; ISO14001 ; OHSMS18001 ; * CE * USA FDA * Maximum X-ray leakage of less than 5 μSv/h(0.5mR/h) measured at 5cm from any external surface. (European standard - less than 1 μSv/h(0.1mR/h) measured at 10cm from any external surface) |
National (China) | * Health Inspection Report * Computer Software Copyright Registration Certificate * Software Product Registration Certificate * Radiation Safety Certificate from Ministry of Public Security * Quality Certification from Safety and Police Electronic Products Quality Inspection Center * Design pantent certification: Patent No. : 201020700245.2 ; Patent No. : 201020700245.8 ; Patent No. : 201020700256.0 |
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
Â
               X-Ray Baggage Scanner                             Product Index | |||||
NO. | Â Â Model | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Remarks | |||
Tunnel Size | Generator | View | Brands of Generator | ||
1 | AT 5030C | 500*300mme | single | one | self made |
2 | AT 6040B | 600*400mm | single | one | Spellman 160 Kv |
3 | AT 6550B | 650*500mm | single | one | Spellman 160 Kv |
4 | AT 8065B | 800*650mm | single | one | Spellman 160 Kv |
5 | AT 10080B | 1000*800mm | single | one | Spellman 160 Kv |
6 | AT 10080D | 1000*800mm | two | two | self made |
7 | AT 10080T | 1000*800mm | three | three view / 3D | self made |
8 | AT 100100B | 1000*1000mm | single | one | Spellman 160 Kv |
9 | AT 100150B | 1000*1500mm | single | one | Spellman 200 Kv |
10 | AT 150180B | 1500*1800mm | single | one | Spellman 200 Kv |
11 | AT 2300 | Portable and mobile x-ray scanner | |||
Available and customizable models | |||||
NO. | Model | Remarks | |||
Tunnel Size | Generator | View | Brands of Generator | ||
1 | AT 100100D | 1000*1000mm | two | two | self made |
2 | AT 100100T | 1000*1000mm | three | three view / 3D | self made |
3 | AT 150100B | 1500*1000mm | single | one | Spellman 160 Kv |
4 | AT 100150D | 1000*1500mm | two | two | self made |
5 | AT 150180D | 1500*1800mm | two | two | self made |
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
Product highlights
* Multilingual operation
* Automatic built in test and self diagnosis
* Secure access Key
* Uninterruptable power supply (UPS)
* Threat alert and material classification
* Auto archiving
* Network-Ready
* Energy saving design
* One key turn off
* Drugs and explosives inspection
* Indication of the date and time
* baggage counter
Physical Specifications | Â |
Unit weight (kgs) | 455 |
Unit size (mm) | 2007.5(L)*868(W)*1314(H) |
after packed in wooden pallet -Â | Â |
Gross weight (kgs) | 500 |
Packing size | #1: 212*101*156cm |
 | #2: 87*87*141cm |
 | |
General Specifications | Â |
Tunnel size(mm) | 615(L)*418(W) |
Conveyor Speed(m/s) | 0.22 |
Conveyor height(mm)Â | 680.5 |
Conveyor Max Load(kgs) | 150 |
X ray dose per each inspection | 1.5 μGy |
X ray leakage | <0.25 μGy / h |
Penetration | 43mm steel |
Wire Resolution | dia 0.0787mm copper wire (AWG40) |
Penetration Resolution | dia 0.16mm copper wire (AWG34) under three-step aluminum wedge 9.5mm, 15.9mm, 22.2mm |
Spatial resolution: | dia1.0mm,Vertical: dia1.0mm |
Power Consumption | max. 1KW |
Noise | < 58 dB |
Film Safety | Guarantee ASA/ISO1600 Film |
 |  |
X-ray Generator (single) | Â |
Anode Voltage | Spellman 160 KV |
Anode power | 0.4-1.2mA (adjustable) |
Generate angle | 80 degree upward |
Generate direct | from bottom to top |
Cooling / Duty Cycle | Oil Cooling /100%Â |
Brand | Spellman |
 |  |
Image System | Â |
X-ray Sensor | L-Shaped Photodiode Array (multi-energetic)Â , 12bit Deep |
Image Display | High resolution of 1024 * 1280 pixel; Image Grey Level: 4096 |
Image Enhancement | 1-64times enlargement continuity, Color/BW, negative, high/low penetration, organic /inorganic Stripping, general enhancement, and pseudo color, etc. |
Image Recall | Â All preceding images recallable, retrieval |
Explosives & Narcotics Detection | Explosives & narcotics alarm and highlight according to atomic number signature |
High Density Region Alarm | Impenetrable region alarm and highlight, for possible concealing of threats and contrabands |
Threat Image Projection | Inserting fictional, but realistic images of threat items into baggage during screening operation, for maintenance of vigilance, as well as training and assessment of image identification capability |
Image Archive | Up to 100,000 images stored automatically, enable transferring to USB disk, and converting to JPG, BMP and other general formats |
Miscellaneous Functions | Time/date display, counters, user management, system-on/X-ray-on timers, power on self test, built-in diagnostic facilities, dual-direction scanning, system log, system standby and stimulant training, ADS etc. |
Network Applications | Multiple remote applications available based on Ethernet LAN and windows platform, such as image centralized storage and identify, recheck workstation, and network TIP, etc ( Optional) . |
Images process | 24bit real time processing ,4colors analysis, Images displayed marked date and ID NO ,Count the number of bags |
 |  |
Operating Environment | Â |
Operation temperature/Humidity |  0ºC-45ºC / 5%-95%(non-condensing) |
Storage Temperature/Humidity |  -40ºCto 70ºC / 5%-95%(non-condensing) |
Operation Power |  220VAC(±10%) 50±3Hz (Optional: 100VAC,110VAC,120VAC,200VAC) |
UPS | Â 15mins, 30mins, 60mins etc, optional |
 |  |
Computer and other | Â |
Monitor | High Resolution Color, LCD Accord, 17inch |
Hard Disk | SEAGATE 500G 3.5" |
CPU | G1610 2.6G |
Storage | 2GB 1600MHz DDR3 Innodisk |
Main board | H61 SYM76993VGGAÂ |
 |  |
Compliance | Â |
International | * ISO19001 ; ISO14001 ; OHSMS18001 ; * CE * USA FDA * Maximum X-ray leakage of less than 5 μSv/h(0.5mR/h) measured at 5cm from any external surface. (European standard - less than 1 μSv/h(0.1mR/h) measured at 10cm from any external surface) |
National (China) | * Health Inspection Report * Computer Software Copyright Registration Certificate * Software Product Registration Certificate * Radiation Safety Certificate from Ministry of Public Security * Quality Certification from Safety and Police Electronic Products Quality Inspection Center * Design pantent certification: Patent No. : 201020700245.2 ; Patent No. : 201020700245.8 ; Patent No. : 201020700256.0 |
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
Â
               X-Ray Baggage Scanner                             Product Index | |||||
NO. | Â Â Model | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Remarks | |||
Tunnel Size | Generator | View | Brands of Generator | ||
1 | AT 5030C | 500*300mme | single | one | self made |
2 | AT 6040B | 600*400mm | single | one | Spellman 160 Kv |
3 | AT 6550B | 650*500mm | single | one | Spellman 160 Kv |
4 | AT 8065B | 800*650mm | single | one | Spellman 160 Kv |
5 | AT 10080B | 1000*800mm | single | one | Spellman 160 Kv |
6 | AT 10080D | 1000*800mm | two | two | self made |
7 | AT 10080T | 1000*800mm | three | three view / 3D | self made |
8 | AT 100100B | 1000*1000mm | single | one | Spellman 160 Kv |
9 | AT 100150B | 1000*1500mm | single | one | Spellman 200 Kv |
10 | AT 150180B | 1500*1800mm | single | one | Spellman 200 Kv |
11 | AT 2300 | Portable and mobile x-ray scanner | |||
Available and customizable models | |||||
NO. | Model | Remarks | |||
Tunnel Size | Generator | View | Brands of Generator | ||
1 | AT 100100D | 1000*1000mm | two | two | self made |
2 | AT 100100T | 1000*1000mm | three | three view / 3D | self made |
3 | AT 150100B | 1500*1000mm | single | one | Spellman 160 Kv |
4 | AT 100150D | 1000*1500mm | two | two | self made |
5 | AT 150180D | 1500*1800mm | two | two | self made |
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
Product Description:
Electric Linear Actuator For Medical Bed
Hospitals across the world face a reality in which there are fewer staff to attend to an increasing number of patients. Those currently in need include the elderly, obese, and patients with multiple diagnoses. Both trends call for improved applications able to help improve comfort for patients, ergonomics for staff and efficiency levels for hospitals. Using Electric Medical Bed actuator systems to provide movement and intelligent features in hospital beds will allow manufacturers to meet demands and have several advantages in a fierce market.
Hospital Bed Motor Actuator Parts has been revolutionized by customizable technologies, notably electric linear actuators. From lift chair and patient hoist actuators to hospital bed actuators, Xinyi Bed Actuator has provided manufacturers with medically certified linear motion products which have been designed specifically for the healthcare industry. These products are used to make healthcare and home settings safer and more efficient than ever.
Technical data:
Input voltage:12VDC/24VDC/36VDC
Max.load:Thrust 6000N,Pull 4000N
Speed: (5mm/s 6000N) (10mm/s 3000N) (20mm/s 2000N) (40mm/s 800N)
Duty cycle:10%,stop for 18 mins after continuoulsy working 2 mins
Ip grade:IP 54
Limit switch:Built-in limit switch,non-adjustable
Operation temperature:+5℃~40℃
Min.install dimension:285mm(175+stroke) [From center of Mounting Holes]
Max.stroke:450mm
Tail connector:90º rotation available
Memory function:optional
Colour:Black/Grey
Linear Actuators For Medical Care
High Speed Linear Actuator 12V,Patient Lift Motor,Medical Care Motor,Linear Actuators For Medical Care
ZHEJIANG XINYI INTELLIGENT DRIVE TECHNOLOGY CO.,LTD , https://www.xinyiactuators.com