TES TES-593 electromagnetic wave pollution intensity meter quoted in the following four regions, quoted in Shanghai area is 2140-2600 yuan, quoted in Guangdong area is 1824-2280 yuan, quoted in Jiangsu area is 1840-2250 yuan, in Fujian The area is quoted at 2330-2350 yuan.

Product Name Brand Model Area Price (RMB   RMB/piece) Electromagnetic wave pollution intensity meter TES TES-593 Shanghai 2140-2600 Guangdong 1824-2280 Jiangsu 1840-2250 Fujian 2330-2350
TES593 electromagnetic radiation detector Introduction:

â—† Test frequency range from 10MHz to 8GHz â—† Measurement of an isotropic electromagnetic field â—† Measurement without direction using a 3-axis measurement sensor bar â—† High dynamic range using a 3-channel digital location â—† Programmable alarm limits and storage functions â—† Safe and easy to use â—† High Frequency (RF) Electromagnetic Wave Intensity Measurements â—† Big Brother Large Base Station Antenna Electromagnetic Wave Radiating Intensity Measurement â—† Wireless Communication Applications (CW, TDMA, GSM, DECT)

â—†RF high-frequency electromagnetic wave security â—†RF high-frequency transmitter power measurement â—†Wireless network (Wi-Fi) detection, installation â—†Wireless pin camera and detection â—† Home wireless phone electromagnetic radiation intensity measurement â—†Microwave radiation leak detection Measurement â—† Company or home environment electromagnetic wave security assessment TES593 electromagnetic radiation detector Detailed parameters:

Sensor Type Electric Field (E) Frequency Range 10MHz   To   8GHz direction characteristic isotropic, 3-axis measurement range (CW signal >50MHz) 20mV/m   To   108.0V/m   53μW/m   To   286.
4mA/m   1μW/   Cm2   To   30.
93W/   M2   0μW/cm2   To   3.093mW/   Cm2 dynamic range about 75dB absolute error (@1V/m and 50MHz)   ±   1.0dB Frequency Response (Correction Factor CAL Inclusion) ±   1.0dB   (50MHz   To   1.9   GHz)   ,    ±2.4dB (1.9GHz   To   35GHz) Isometric Deviation   About ±1.0dB at f>50   MHz Continuous Wave Overload Limit (CW) 4.2W/m2   (40   V/m) Temperature Effect (0 to 50°C) ±   1.5dB Measurement Method Digital Triaxial Measurements Approximately 67 (W) X60 (H) X247 (L) mm Weight Approx. 260 g (with battery) General Specifications Measurement Methods Digital Three-axis Measurement Direction Features Isometric, 3-Axis Measurements Range Select a continuous display resolution of 0.1mV/m, 0.1μA/m, 0.1μW   /   M2, 0.001μW/   Cm2 Response time is about one second (measured value from 0 to 90%) Alarm buzzer Measurement unit mV/m, V/m, μA/m, mA/m, μW   /   M2,mW   /   M2,μW/   Cm2 Measured Display Values ​​Instant Measured, Maximum Measured, Mean Measured, and Maximum Average Display LCD   4-digit measurement alarm function Adjustable set value and can be turned on or off Measurement correction factor (CLD) Adjustable manual data storage and reading 99 groups (can only be read on the table) Dry battery 9V Battery life> 15 hours Size approx. 67(W) X60(H) X247(L)mm Weight 260g (with battery)