Abstract: Due to the simple structure and easy installation of the vortex flowmeter, the vortex flowmeter can also be used for measurement when measuring compressed air, and also inherits the advantages of the vortex flowmeter , although there are many advantages, but Users will still have various problems during their use.
Let's discuss the specific solution together with the problem.
1. The correct selection and scientific installation in the early stage should consider the interference of the surrounding environment signal of the instrument during installation;
2. If the flow of compressed air is only used to control the flow, it can be used routinely. When the interests of the buyer and the seller are involved, the temperature and pressure need to be compensated, that is, the temperature-compensated vortex flowmeter needs to be selected;
3. The Reynolds coefficient of the medium needs to be greater than 2×104 or more, otherwise there will be errors;
4. The nature of the medium to be tested at the time of selection requires the properties of the medium in the actual pipeline to be consistent. If it is inconsistent, it needs to be re-selected according to the nature of the medium in the pipeline;
5. When installing the compressed air flowmeter, keep away from the power source or other frequently changing valves. When the installation pipeline is vibrating, consider installing the fixed bracket on the pipeline, and less errors caused by vibration.
6. If the temperature and pressure compensation type vortex flowmeter is installed, when installing the temperature sensor and the pressure transmitter, the distance of 5~8D downstream of the compressed air flowmeter should be suitable;
7. When the split type compressed air flow meter is selected, our factory will be equipped with a 10 meter cable. When using the cable, use the installed cable and make grounding measures.
8. The load from the signal output of the compressed air flow meter should not exceed the specified value;
9. The installation environment of the compressed air flow meter should try to avoid the environment with high current and strong magnetic field around;
Summary: As can be seen from the above analysis, some common problems can be avoided during installation. Therefore, it is recommended to read the installation instructions in detail when purchasing the instrument to avoid unnecessary loss due to improper installation.
1.SK FMB Face Milling Arbors Cnc Milling Tool Holders , used in the clamping of the cutter with the radial drive groove, such as the face milling cutter, the vertical disc cutter, the set type end mill, high speed and high precision machining .Mechanical spindle and cutting tools and Other Accessories.High Precision SK shank Tool Holder ,balanced G6.3 or G2.5 For choose.
2.Proove cleanness,precsion more stable ,surface more smooth,feel more comfortable and appearance nicer. Chuck surface is coated ,the layer is evenly ,Chemical plating solution dispersion degree of almost 100%,nickel layer is thin .This special coating can reduce Spindle abnormal wear and tear.Don't influence precision .
3.we can to figure to sample processing, and perfect after-sales service and technical support. Looking forward to your cooperation!
Sk Fmb Face Mill Holder,Sk Face Mill Holder,Shank Face Mill Holder,Sk Shank Face Mill Holder
Shandong Chongde Precision Machinery Co.,LTD , https://www.springcollet.com